|
Energy efficient and superior quality instrument transformers...
About Us
The
company was incorporated under the Companies Act, 1956, vide
Incorporation Certificate No.20-5489, dated 01-12-1981, with Registrar
of Companies, (U.P.), Kanpur.
The company is presently being
managed by Mr. S.K. Mishra (Ex-Major) with the help of
vastly experienced team of technical and administrative executives.
The
company
is in the business of manufacturing and supplying Instrument
Transformers up to 132 KV Class since 1983. The company has
manufactured
and supplied its products to almost all the Electricity Boards and
utilities in the country. The company's name figures in the list of
Registered / Approved Vendors of C.S.E.B., N.T.PC., MPPTCL, BBMB, BHPC,
NHPC, OHPC, GGSSTP, distribution & transmission companies of UPPCL,
power and development Department (J & K) and other organizations.
The
company
work's is located in Greater Noida on company's property measuring 3200
sq. meter., having a covered area of 15,000 ft. The place is very well
connected with Delhi, Ghaziabad, and other regions.
Product Profile
Instrument Transformers
Transformer intended to supply to measuring instruments, meters, relays and other similar apparatus is called an instrument transformer. They are either - Current Transformers or Potential Transformers. Current Transformer
Direct measurement of current in H.V. system is not possible because of the insulation problem of measuring instruments. It is also not possible to use current flowing through the system, directly for protection purpose due to its high value and high insulation problem. Therefore, CT is designed to be used for the following purposes:- a) To reduce the line Current to a value suitable for supply to measuring instruments, relays, breakers, etc. b) To isolate measuring instruments from high voltage side of installation c) To protect measuring instruments against short circuit current d) To sense the fault in Current and Operate relays in order to isolate the faulty part of the system. Potential Transformer
Since it is difficult to measure high system voltage due to insulation problem of measuring instruments. The P.T. is designed for the measurement of High System Voltage by stepping it down to a value suitable for the measuring instrument. The P.T. can be used for:- a) Metering: P.T. with single secondary winding b) Protection: For this purpose an additional secondary winding is provided which is connected in open delta so that in the event of an earth fault on any of the phases, appropriate voltage is developed across open delta terminals which in turn actuates a tripping mechanism.
Product Range
Macroplast Pvt. Ltd. is manufacturing the following products:- - L.T. CTs
- 11 KV CTs (Dry & Oil Immersed)
- 11 KV PTs (Dry & Oil Immersed)
- 11 KV CT / PT Metering Unit
- 33 KV CTs
- 33 KV PTs
- 33 KV CT / PT Metering Units
- 66 KV CTs
- 66 KV PTs
- 132 KV CTs
- 132 KV PTs
- 11 KV Metering Cubicles.
Manufacturing & Testing Facilities
- Total area of factory 32000 sqft.
- Shop floor area of 15000 sqft.
- Coil winding & insulation is carried out in dust free air conditioned rooms
- State-of-the-art dehydration chambers along with vacuum plant achieving vacuum of 0.05 Torr with dedicated oil filtration plant
- Adequate oil storage facility
- All routine
test facilities as per IS-2705/1992 & IEC for current Transformers
& as per IS-3156/1992 & IEC for voltage transformers
- Type test facilities like temperature rise, ISF, Partial discharge, ten delta & capacitance
- Oil break down voltage test set
- Office
area of 2000 sq. ft. with facilities like networked computers,
printers, UPS, copiers, faxes & emails for efficient working
- Computerized records are maintained in all departments like stores, accounts, marketing, purchase & designs
- All drawings drafted on Auto cad
- Generator back-up to ensure continuous power supply
- In-house facility for fabrication of tanks to meet any urgent requirement of our esteemed customers.
Experience
Our
company was established with the aim of providing premium quality
Instrument Transformers to the clients. With vast experience in the
industry over the years, we have achieved expertise in all endeavors.
The
company invests hugely in the development of different designs of
instrument transformers. In order to achieve perfection and efficacy,
the company regularly gets its products Type Tested in different
government approved laboratories like CPRI & ERDA, NTH, etc. The
company holds all the relevant Type Tests as per ISS 2705, ISS
3156 & IEC in respect of its entire range of products.
Clients All
State Electricity boards & some leading electrical contractors such
as IVRCL, SMS Infrastructure Ltd., Bajaj Electricals Ltd., JOP Power
Infra Engineering Ltd. Our efforts
have helped us to develop a strong customer base in India. Some of our
major clients include NTPC,
MPPTCL,CSEB, BBMB, BHPC, NHPC, OHPC, GGSSTP, distribution &
transmission
companies of UPPCL, power and development Department (J & K) and
many others.
|
Contact Details |
|
|
|
MACROPLAST PVT. LTD. |
D-18/2, Surajpur Industrial Area, Site-B, Gautam Budh Nagar,Noida - 201306, Uttar Pradesh, India Phone:91-120-2560717/2569140 Fax:91-120-2560717

Contact Now
|
Key Personnel |
Mr. S. K. Mishra
(C & MD)
Mobile:+919810846303 Mr. S. K. Tiwari
(Manager Sales & Technical)
Mobile:+919818043521 Mr. Suresh Kumar Misra
(Manager Sales & Commercial )
Mobile:+919717610605
|
|
|
|
|
|